<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="other" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Russian Journal of Infection and Immunity</journal-id><journal-title-group><journal-title xml:lang="en">Russian Journal of Infection and Immunity</journal-title><trans-title-group xml:lang="ru"><trans-title>Инфекция и иммунитет</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2220-7619</issn><issn publication-format="electronic">2313-7398</issn><publisher><publisher-name xml:lang="en">SPb RAACI</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">647</article-id><article-id pub-id-type="doi">10.15789/2220-7619-2019-2-385-392</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>METHODS</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>МЕТОДЫ</subject></subj-group><subj-group subj-group-type="article-type"><subject></subject></subj-group></article-categories><title-group><article-title xml:lang="en">Coherent fluctuation nephelometry in clinical microbiology</article-title><trans-title-group xml:lang="ru"><trans-title>Когерентная флуктуационная нефелометрия в клинической микробиологии</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8823-7819</contrib-id><name-alternatives><name xml:lang="en"><surname>Gur’ev</surname><given-names>A. S.</given-names></name><name xml:lang="ru"><surname>Гурьев</surname><given-names>А. С.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD, Senior Researcher, Research Laboratory, M.F. Vladimirsky Moscow Regional Clinical and Research Institute (MONIKI); Researcher, Medtechnopark Ltd.</p><p><bold><italic>Contacts:</italic></bold><italic> Alexander S. Gur’ev 129110, Russian Federation, Moscow, Shchepkina str., 61/2, M.F. Vladimirsky Moscow Regional Research and Clinical Institute (MONIKI). Phone: +7 (906) 062-06-73.</italic></p></bio><bio xml:lang="ru"><p><bold>Гурьев Александр Сергеевич</bold>, PhD, старший научный сотрудник МОНИКИ им. М.Ф. Владимирского; научный сотрудник ООО «Медтехнопарк»</p><p><bold><italic>Адрес для переписки: </italic></bold><italic>Гурьев Александр Сергеевич 129110, Россия, Москва, ул. Щепкина, 61/2, корп. 1, ГБУЗ МО МОНИКИ им. М.Ф. Владимирского. Тел.: 8 (906) 062-06-73.</italic></p></bio><email>coherneph@mail.ru</email><xref ref-type="aff" rid="aff1"/><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Shalatova</surname><given-names>O. Yu.</given-names></name><name xml:lang="ru"><surname>Шалатова</surname><given-names>О. Ю.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>Junior Researcher, Laboratory of Biopreparations, Innovative Technologies Departmen ussian Federation; Researcher</p></bio><bio xml:lang="ru"><p><bold>Шалатова</bold> <bold>Ольга Юрьевна</bold>, младший научный сотрудник лаборатории биопрепаратов Отдела новых технологий</p></bio><email>ont_olga@mail.ru</email><xref ref-type="aff" rid="aff3"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Rusanova</surname><given-names>E. V.</given-names></name><name xml:lang="ru"><surname>Русанова</surname><given-names>Е. В.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, PhD, Lead Researcher, Research Laboratory, M.F. Vladimirsky MONIKI; Chief Supernumerary Specialist in Bacteriology, Department of Healthcare of the Moscow Region</p></bio><bio xml:lang="ru"><p><bold>Русанова Елена Владимировна</bold>, кандидат медицинских наук, ведущий научный сотрудник научно-исследовательской лаборатории лабораторного отдела ГБУЗ МО МОНИКИ им. М.Ф. Владимирского, главный внештатный бактериолог МЗ МО России</p></bio><email>rusanova.microbiolog@yandex.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6374-9786</contrib-id><name-alternatives><name xml:lang="en"><surname>Vasilenko</surname><given-names>I. V.</given-names></name><name xml:lang="ru"><surname>Василенко</surname><given-names>И. А.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD, MD (Medicine), Professor, Head of the Research Laboratory ussian Federation; Researcher</p></bio><bio xml:lang="ru"><p><bold>Василенко Ирина Анатольевна</bold>, доктор мендицинских наук, профессор, зав. научноисследовательской лабораторией лабораторного отдела</p></bio><email>vasilenko0604@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-5110-553X</contrib-id><name-alternatives><name xml:lang="en"><surname>Volkov</surname><given-names>A. Yu.</given-names></name><name xml:lang="ru"><surname>Волков</surname><given-names>А. Ю.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD (Physics and Mathematics), Director of Medtechnopark LTD</p></bio><bio xml:lang="ru"><p><bold>Волков Алексей Юрьевич</bold>, кандидат-физико-математических наук, генеральный директор ООО «Медтехнопарк»</p></bio><email>md.volkov@mail.ru</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Moscow Regional Research and Clinical Institute (MONIKI)</institution></aff><aff><institution xml:lang="ru">ГБУЗ МО Московский областной научно-исследовательский клинический институт им. М.Ф. Владимирского</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">Medtechnopark Ltd.</institution></aff><aff><institution xml:lang="ru">ООО "Медтехнопарк"</institution></aff></aff-alternatives><aff-alternatives id="aff3"><aff><institution xml:lang="en">Pasteur Institute of Epidemiology and Microbiology</institution></aff><aff><institution xml:lang="ru">ФБУН НИИ эпидемиологии и микробиологии имени Пастера</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2019-07-12" publication-format="electronic"><day>12</day><month>07</month><year>2019</year></pub-date><volume>9</volume><issue>2</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>385</fpage><lpage>392</lpage><history><date date-type="received" iso-8601-date="2018-04-24"><day>24</day><month>04</month><year>2018</year></date><date date-type="accepted" iso-8601-date="2019-04-17"><day>17</day><month>04</month><year>2019</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2019, Gur’ev A.S., Shalatova O.Y., Rusanova E.V., Vasilenko I.V., Volkov A.Y.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2019, Гурьев А.С., Шалатова О.Ю., Русанова Е.В., Василенко И.А., Волков А.Ю.</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="en">Gur’ev A.S., Shalatova O.Y., Rusanova E.V., Vasilenko I.V., Volkov A.Y.</copyright-holder><copyright-holder xml:lang="ru">Гурьев А.С., Шалатова О.Ю., Русанова Е.В., Василенко И.А., Волков А.Ю.</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://iimmun.ru/iimm/article/view/647">https://iimmun.ru/iimm/article/view/647</self-uri><abstract xml:lang="en"><p>In this article data concerning coherent fluctuation nephelometry (CFN) use in clinical microbiology is presented. CFN-analyzer allows to solve two important problems – fast urine screening for bacteriuria within 2-4 hours and antibiotic susceptibility testing within 3-6 hours. Altogether more than 650 urine samples were tested, and the effectivity of CFN-analyzer for preliminary selection of samples for further analysis was shown. Method allows to detect negative samples, reducing the number of urine analyses by 70-80%. Simultaneous analysis of growth curves and concentration of microorganisms shows high sensitivity and specificity (95.2% и 96.9%). Also more than 250 antibiotic susceptibility tests were performed using CFN-analyzer to show its effectiveness for determination of resistant properties of both pure cultures and urine microflora without isolation of bacteria. The agreement with traditional methods was from 84% to 88%. The use of CFN-analyzer with express methods of identification of microorganisms (chromogenic nutrient broths or mass-spectrometry) allows to make full urine analysis within 1-2 days. In the future CFN-analyzer gives an opportunity to screen different human biological liquids, and finds an application for other microbiological tasks, including standardization and speeding-up in sanitary bacteriology.</p></abstract><trans-abstract xml:lang="ru"><p>В статье представлены данные по использованию метода когерентной флуктуационной нефелометрии (КФН) в клинический микробиологической практике. КФН-анализатор позволяет решать две важных задачи – проводить быстрый скрининг мочи на бактериурию за 2-4 часа и определять чувствительность бактериальных культур к антибиотикам за 3-6 часов. В общей сложности исследовано более 650 образцов мочи и показана эффективность КФН-анализатора для предварительного отбора проб на анализ. Метод позволяет выявлять отрицательные образцы, снижая общее количество исследований на 70-80%. Одновременный анализ кривых роста микроорганизмов и их концентрации в моче даёт возможность достигнуть высоких показателей чувствительности и специфичности (95,2% и 96,9%). Также проведено более 250 исследований чувствительности к антибиотикам на КФН-анализаторе, продемонстрирована его высокая эффективность для быстрого определения резистентных свойств как чистых культур, так и микрофлоры мочи без выделения изолятов. Согласие результатов с традиционными методами составило от 84% до 88%. Использование КФН-анализатора совестно с экспресс методами видовой идентификации микроорганизмов (хромогенными питательными средами или масс-спектрометрическим методом) позволит проводить полный анализ мочи за один-два дня. В перспективе КФН-анализатор даст возможность проводить скрининг различных биологических жидкостей человека, а также найдёт применение в широком круге микробиологических задач, в том числе, для ускорения и стандартизации санитарно-биологических исследований.</p></trans-abstract><kwd-group xml:lang="en"><kwd>coherent fluctuation nephelometry</kwd><kwd>bacteriuria</kwd><kwd>screening</kwd><kwd>urine antibiotic susceptibility testing</kwd><kwd>microbiology analyzer</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>когерентная флуктуационная нефелометрия</kwd><kwd>бактериурия</kwd><kwd>скрининг</kwd><kwd>моча</kwd><kwd>определение чувствительности к антибиотикам</kwd><kwd>микробиологический анализатор</kwd></kwd-group><funding-group><funding-statement xml:lang="en">Medtechnopark Ltd.</funding-statement><funding-statement xml:lang="ru">ООО "Медтехнопарк"</funding-statement></funding-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Баранов А.А., Маянский А.Н., Чеботарь И.В., Маянский Н.А. Новая эпоха в медицинской микробиологии // Вестник Российской Академии наук. 2015. Т. 85, № 6. С. 907–909. doi: 10.1134/S1019331615060015</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>2. Гурьев А.С., Волков А.Ю., Долгушин И.И., Поспелова А.В., Растопов С.Ф., Савочкина А.Ю., Сергиенко В.И. Когерентная флуктуационная нефелометрия — быстрый метод скрининга мочи на микробную обсемененность // Бюллетень экспериментальной биологии и медицины. 2015. Т. 159, № 1. С. 120–123. doi: 10.1007/s10517-015-2902-0</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>3. Гурьев А.С., Кузнецова О.Ю., Пясецкая М.Ф., Смирнова И.А., Беляева Н.А., Вербов В.Н., Волков А.Ю. Быстрый скрининг мочи на бактериурию у детей с использованием микробиологического анализатора, совмещающего в себе методы фотометрии и когерентной флуктуационной нефелометрии // Инфекция и иммунитет. 2016. Т. 6, № 4. С. 395–398. doi: 10.15789/2220-7619-2016-4-395-398</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>4. Растопов С.Ф. Когерентная флуктуационная нефелометрия: высокочувствительный метод детектирования частиц в жидкости // Приборы и техника эксперимента. 2011. Т. 54, № 6. С. 95–99. doi: 10.1134/S0020441211060194</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>5. Станкевич Л.И., Герасимова. Е.С., Загорельский В.В. Скрининг бактериурии с помощью автоматизированной проточной цитометрии на анализаторе UF1000i Sysmex как инструмент для отбора образцов мочи на посев // Поликлиника. 2014. Т. 4, № 1. С. 13–16.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>6. Davenport M., Mach K.E., Shortliffe L.M.D., Banaei N., Wang T.H., Liao J.C. New and developing diagnostic technologies for urinary tract infections. Nat. Rev. Urol., 2017, vol. 14, no. 5, pp. 296–310. doi: 10.1038/nrurol.2017.20</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>7. Gur’ev A.S., Kuznetsova O.Yu., Kraeva L.A., Rastopov S.F., Verbov V.N., Vasilenko I.A., Rusanova E.V., Volkov A.Yu. Development of microbiological analyzer based on coherent fluctuation nephelometry. In: Advances in artificial systems for medicine and education. Eds. Hu Z., Petoukhov S., He M. Springer, 2018, vol. 658, pp. 198–206. doi: 10.1007/978-3-319-67349-3_18</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>8. Gur’ev A.S., Yudina I.E., Lazareva A.V., Volkov A.Yu. Coherent fluctuation nephelometry as a promising method for diagnosis of bacteriuria. Pract. Lab. Med., 2018, vol. 12: e00106. doi: 10.1016/j.plabm.2018.e00106</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>9. Maia M.R., Marques S., Cabrita A.R., Wallace R.J., Thompson G., Fonseca A.J., Oliveira H.M. Simple and versatile turbidimetric monitoring of bacterial growth in liquid cultures using a customized 3D printed culture tube holder and a miniaturized spectrophotometer: application to facultative and strictly anaerobic bacteria. Front. Microbiol., 2016, no. 7, pp. 1381. doi: 10.3389/fmicb.2016.01381</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>10. U.S. EPA. Detection of biological suspensions using online detectors in a drinking water distribution system simulator. U.S. Environmental Protection Agency, 2010, EPA/600/R-10/005</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>11. Zapata A., Ramirez-Arcos S. A comparative study of McFarland turbidity standards and the Densimat photometer to determine bacterial cell density. Curr. Microbiol., 2015, vol. 70, no. 6, pp. 907–909. doi: 10.1007/s00284-015-0801</mixed-citation></ref></ref-list></back></article>
